MEI HT5000 NOTES: This is a dual NAM handheld unit. The ESN prefix is 167 decimal, A7 hex. Monsor Electronics: 416-475-8444 PROGRAMMING: 1. With the power OFF plug in the programing adaptor, if this is not available short pins 1 and 6 (end pins on the top row). 2. Power the phone up by pressing and holding the PWR button, the phone will go straight into programing mode. 3. RCL enters data and increments the step number. 4. MUT increments the step number without storing data. 5. SND decrements the step number without storing data. 6. At any time END completes programing and exits. Wait at least 3 seconds before turning the power off. PROGRAMING DATA: STEP# #OF DIGITS/RANGE DESCRIPTION 01 0 OR 1 ALLOW USER A/B SWITCHING 02 0 OR 1 LOW BATTERY ALARM 03 0 OR 1 0= 10 MEM LOCATIONS, 1=100 MEM LOCATIONS 04 0 OR 1 ROAM ENABLE 05 0 OR 1 DTMF DIALLING (END TO END) 06 0 OR 1 HORN ALERT 07 0 OR 1 0= NUMERIC MEM, 1= ALPHA MEM 08 0 OR 1 MUSIC ON MUTE 09 0 OR 1 USER CUMULATIVE TIMER RESET 10 0 OR 1 AUTO METER SWITCH FROM BATT LEVEL TO RSSI 11 NOT USED 12 0 OR 1 LOCK CODE REQUIRED TO RESET AIR TIMER 13 0 OR 1 LOCK CODE REQUIRED TO DISPLAY MIN 14 NOT USED 16 NOT USED 17 0, 1 OR 2 LOCK MODE 0=TOTAL, 1=OUTGOING ONLY, 3=PARTIAL 18 1 TO 10 DIGITS LOCK CODE 19 0 TO 255 SECONDS BACK LIGHT TIMER 20 10 DIGITS MIN (AREA CODE & TEL NUMBER) 21 00000 - 32767 SYSTEM ID 22 333 OR 334 INITIAL PAGING CHANNEL 23 2 DIGITS STATION CLASS MARK 24 0 OR 1 PREFERRED SYSTEM 0=B, 1=A 25 0 OR 1 MIN MARK 26 2 DIGITS ACCESS OVERLOAD CLASS 27 2 DIGITS GROUP ID (10 IN USA) 28 0 OR 1 LOCAL USE MARK NAM 2 DATA: 29 10 DIGITS MIN (AREA CODE & TEL#) 30 00000 - 32767 SYSTEM ID 31 333 OR 334 INITIAL PAGING CHANNEL 32 2 DIGITS STATION CLASS MARK 33 0 OR 1 PREFERRED SYSTEM 0=B, 1=A LOCK: F 7. UNLOCK: Enter three digit code. SYSTEM SELECT: (Only if step 1 above is set to "1") Press F # 6 to display, 6 to scroll CLR to exit.